Trusted by installers & EPC contractors +91 94171 22679 [email protected]
SOLENIX SOLUTIONS — Power That Holds — Request a Quote
ACDB AC distribution box with MCB and surge protection

Electrical & Earthing · SLX-22

Solar ACDB Box

Also called: ACDB Box, AC distribution box, ACDB panel

A solar ACDB box (AC distribution box) sits between the inverter and the building's electrical board, with an MCB to isolate the inverter and surge protection on the AC side. Solenix Solutions supplies pre-wired ACDB boxes in ratings from 32 A to 300 A from Jalandhar, Punjab, across India.

Supplied from Jalandhar, Punjab · Pan-India dispatch · Same-day quotes

Specifications

Material & gradePlastic box and electrical equipment
Sizes / variants32 A to 300 A
Pack size10 sets/carton
MOQ10 sets
HSN code85369090
Lead timeSame-day dispatch

What an ACDB does

The ACDB takes the inverter's AC output and protects it on its way to the distribution board and the grid. The MCB lets you isolate the inverter for maintenance and trips on overload or short circuit. The surge protection device (SPD) diverts voltage spikes to earth before they reach the inverter.

Ours come pre-wired in a plastic enclosure, ready to mount and wire.

Choosing a solar ACDB box

Size the ACDB to the inverter: its rating should suit the inverter's maximum AC output current, and it must match the supply, single-phase or three-phase. We keep all types, from 32 A to 300 A: tell us the inverter's kW rating, its phase and the number of inverters, and we will suggest the box.

Mount it close to the inverter, out of direct rain, and connect the SPD's earth to the AC earthing.

Ordering

ACDB boxes are packed by the carton; the table above lists the pack size and minimum order. Send the ratings and quantities on WhatsApp for a same-day rate. DCDB boxes, AC and DC wire and earthing can go in the same order.

Frequently asked questions

What is the difference between an ACDB and a DCDB?

The DCDB sits on the DC side, between the solar panels and the inverter, with fuses and DC surge protection. The ACDB sits on the AC side, between the inverter and the building's board, with an MCB and AC surge protection. A grid-tied system usually needs both.

Which ACDB rating do I need?

It depends on the inverter's AC output current and on whether the supply is single-phase or three-phase. Send the inverter's kW rating and phase on WhatsApp, and we will suggest a rating from our 32 A to 300 A range.

Does the ACDB come pre-wired?

Yes. The boxes come wired with the MCB and surge protection in place, so on site you mount the box and connect the incoming and outgoing cables.

Need a wholesale quote?

Send your product list and quantities on WhatsApp. We reply with rates the same day.