Copper Bonded Earthing Rod
Copper-bonded earthing rods for low-resistance grounding of solar arrays — long service life even in aggressive soil.
SOLENIX
SOLUTIONS
— Power That Holds —
Request a Quote
Electrical & Earthing · SLX-27
Also called: Copper Bonded Lightning Arrester, solar lightning arrester, copper bonded LA
A copper bonded lightning arrester (LA) is mounted above a rooftop solar array to intercept lightning strikes and carry the current safely to earth, protecting the panels and the inverter. Solenix Solutions supplies 1 m copper-bonded lightning arresters, each with a PVC base and five spikes, from Jalandhar, Punjab, with pan-India dispatch.
Supplied from Jalandhar, Punjab · Pan-India dispatch · Same-day quotes
| Material & grade | MS (mild steel) |
|---|---|
| Thickness / section | 17 mm |
| Coating | Copper bonded, 80 µm |
| Sizes / variants | 1 m |
| Pack size | 10 pcs/bundle |
| MOQ | 10 pcs |
| HSN code | 72159090 |
| Lead time | Same-day dispatch |
The LA is the highest point on the roof, so a strike hits its tip instead of the panels. A down conductor then carries the current to its own earth pit, away from the solar equipment. The whole array has to sit inside the LA's zone of protection, which is why its height and position matter.
Ours are 17 mm copper-bonded MS (mild steel), 1 m long. Each comes with a PVC base that the rod stands on and five spikes that fit on top to form its head.
Mount the LA so that it stands clear above the array, and fix the PVC base firmly against the wind. Run the down conductor by the shortest, straightest route to an earth pit with a copper bonded earthing rod, keep it clear of the panel wiring, and test the pit's earth resistance after installation.
LAs are packed in bundles; the table above gives the pack size and minimum order. Tell us the roof size and array layout on WhatsApp, and we will quote the LA and earthing rods together the same day.
Rooftop project specifications in India usually include one, because the array sits on the most exposed part of the building. Check the requirements for your project or DISCOM before you order.
High enough that the whole array falls inside its zone of protection. Larger arrays need the arrester mounted higher, or more than one, and the system designer works this out from the roof layout. Ours is 1 m long.
A PVC base and five spikes. The 1 m copper-bonded rod stands on the base, and the spikes fit on top of it to form the head.
Send your product list and quantities on WhatsApp. We reply with rates the same day.